Model 411-HMI

Features:

  • Color touch-screen interface
  • Modular configuration is highly customizable
  • Wide measurement range up to 6.5 decades, single ionization chamber (not gamma compensated)
  • Select ion chamber size: single 2L typical
  • Upgraded alarm system: two adjustable tritium level alarms, latching and non-latching alarm modes, malfunction and low flow alarms, and up to 3 alarm relays (two level, one malfunction)
  • Visual and audible alarm indicators
  • Alpha pulse suppression, radon rejection
  • Long-term zero stable, span calibration is permanently stable due to special electrometer design
  • Remote mounting of ionization chamber (25 feet standard)
  • Ethernet output

Description:

The Model 411-HMI is based on the Model 411 but includes an integrated computer and color touch-screen display HMI instead of the standard digital panel meter display.  The color-touch screen HMI handles all control (alarm set-points, measurement units), alarm indicator, and display functions.  Includes Ethernet output, low flow alarm, and malfunction alarm indicators (low voltage failure, high voltage failure, or electrometer failure).

The Model 411-HMI features a wide measurement range of up to 6.5 decades with a single ionization chamber (not gamma compensated).  Useful for applications that don’t require gamma compensation or for measuring high concentrations of tritium across a wide range, such as during the manufacture, storage, and processing of tritium.  The Model 411-HMI is part of our modular series, designed for easy customization, and features an upgraded alarm system that includes two adjustable tritium level alarms (alert level and high level) with audible and visual alarm indicators, low flow alarm, malfunction alarm (low voltage failure, high voltage failure, or electrometer failure), acknowledge (mute), latching or non-latching alarm modes, and up to three alarm relays (two level relays and one malfunction relay).

The Model 411 typically supports a single 2L ionization chamber.  Ionization chambers can be mounted remotely (up to 25 feet standard), or locally inside the electronics enclosure.

Typical Measurement Ranges:

Ci Bq
Single 2L: 1 to 199,999 µCi/m3  0.01 to 1,999.9 MBq/m3

Unique, gold-plated wire-grid ionization chambers are offered that are plate-out proof, reducing tritium/gamma contamination by up to 1,000x, which is essential when measuring high levels of tritium.

A wide variety of options are available, including: choice of additional second data output (RS-232, RS-485, 4-20mA), pump type and flowmeter assembly, remote display unit, helium leak testing, wire-grid ionization chambers, gold-plated measurement chamber, HTO only measurement (noble gas compensation), and more.